Installation Precautions
1) The metal case is connected to the internal power source. Be careful not to connect with other external board groups or chassis.
2) the air inlet and outlet where the plane close to the user"s machine wall and the outside of the pores connected to the best installation, such as can not be achieved, the outlet around 2cm without shelter. Between the air inlet and the outlet should be the structure of the air separation, to avoid air flow inside the user from the outlet directly back to the air inlet.
3) The inner wall of the user"s machine shall not be smaller than the size of the air inlet.
4) When applying to the purifier, try to avoid placing the sensor directly in the purifier"s own air duct. If it is unavoidable, set up a separate structural space and place the sensor in the same way as the purifier"s own duct isolation.
5) Application with the purifier or fixed detection equipment, the sensor position should be higher than the ground 20cm or more. Otherwise there may be near the ground of large dust particles and even floc contamination caused by fan winding resistance.
6) sensors used in outdoor fixed equipment, for dust storms, rain and snow and the protection of Yang catkins, should be completed by the equipment.
7) The sensor is an integral part and the user will not disassemble it, including metal shields, to prevent irreversible damage.
8) The bottom of the sensor is fixed with 2mm tapping screw, the screw into the shell length should not be greater than 5mm.